More info
Port of communication VE. Direct
The PORT VE. Direct can be connected to:
A computer (VE interface cable. Direct-USB required).
Apple and Android smartphones, tablets, macbooks and other devices (a Bluetooth Smart electronic key communicating with EV. Direct is required).
Fully configurable
Reset levels and alarm activation in case of low battery voltage
Restart levels and shutdowns in case of low battery voltage
Dynamic cut: cut level depending on the load
Exit Voltage 210 - 245 V
50 Hz or 60 Hz output frequency
ECO detection level and ECO mode ignition/stop
Monitoring
Entry and exit voltage, % charge and alarms
Recognised reliability
The complete bridge topology with a toroidal transformer has demonstrated its reliability for years. Converters are protected from short circuits and overheating, whether in the event of an overload or high ambient temperature.
Strong start-up power
Needed to start loads such as power converters for LED bulbs, halogens or power tools.
Mode ECO
In ECO mode, the converter will switch on pause if the load drops below a predetermined value (minimum charge: 15 W). Once on pause, the converter will turn on for a short period of time (adjustable; by default: every 2.5 seconds). If the load exceeds a pre-configured level, the converter will remain on.
Diagnostic LED
A red LED light and a green indicate how the converter works and the condition of the various protections
On/off remotely
A remote ignition/stop switch can be connected to a connector at two poles or between the positive battery pole and the left contact of the two-pole connector.
To transfer the load to another CA source: the automatic transfer switch
For our low-power converters, we recommend using our Filax automatic transfer switch. The Filax has a very fast transfer time (less than 20 milliseconds) so that computers and other electronic equipment can continue to operate without interruption.
Screw terminals
No specific tools are required for installation.
Characteristics
Phoenix Converter | 12V / 1200 24V / 1200 48V / 1200 |
Continuous power at 25oC (1) | 1200 VA |
Continuous power at 25cc / 40C | 1000 /850 W |
Peak power | 2200 W |
Frequency / CA output voltage (adjustable) | 230 VCA or 120 VCA - 3% 50 Hz or 60 Hz - 0.1% |
Power voltage range | 9.2 - 17 V 18.4 - 34.0 V 36.8 - 62.0 V |
Low CC current stop (adjustable) | 9.3 V 18.6 V 37.2 V |
Dynamics (depending on load) Low CC current stop (fully adjustable) | Dynamic cut |
Alarm and restart CC low (adjustable) | 10.9V 21.8V 43.6V |
Charged battery detection (adjustable) | 14.0V 28.0V 56.0V |
Maximum efficiency | 91 / 91 / 92 % |
Empty consumption | 7 W 8w 10 W |
Default vacuum consumption in ECO mode (default new test interval: 2.5s, adjustable) | 1 1,5 3,0 |
Start and stop power setting in ECO mode | Adjustable |
Protection | A-f |
Operating temperature range | -40 to 65 degrees Celsius (cooling per fan) (Reduction 1.25% by C above 25 degrees Celsius) |
Humidity (without condensation) | max 95% |
Housing | |
Material and colour | Steel frame and plastic cover (Blue RAL 5012) |
Battery connection | Screw terminals |
Maximum cable section | 25 / 10 / 10 mm2 / AWG4 / 8 / 8 |
Standard CA Takes | 230 V: Schuko (CEE 7/4), IEC-320 (male catch included) UK (BS 1363), AU/NZ (AS/NZS 3112) 120 V: Nema 5-15R |
Degree of protection | IP 21 |
Weight | 7.4 kg / 16.3 lbs |
Dimensions (HxLxP in mm) | 117 x 232 x 327 - 4.6 x 9.1 x 12.9 - (12V model: 117 x 232 x 362) |
Accessories | |
Remote on/off switch | Yes |
Automatic transfer switch | FIlax |
Standards | |
Security | EN-IEC 60335-1 / EN-IEC 62109-1 |
Emc | IN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3 |
Automotive Directive | ECE R10-4 |
1) Non-linear load, peak factor 3:1 |
- Number of Reviews : 2
- Average Grade : 5 /5
- C. Jean-michel
- the 10/09/2022
5/5
- G. Xavier
- the 29/03/2022
5/5
Specifications
12V-24V-48V | |
7,4 Kg | |
232 mm | |
117 mm | |
327 mm | |
12000VA |