PROMO
-15%
Inverter/Charger Victron MultiPlus-II GX 48V 3000/5000 View full size

Inverter/Charger Victron MultiPlus-II GX 48V 3000/5000

Victron energy

Options

The MultiPlus-II combines the functions of the MultiPlus and MultiGrid.
It presents all the functions of the MultiPlus, with an external current transformer option to implement the functions of PowerControl and PowerAssist, and to optimize self-consumption with an external current probe (32 A max.).
It also has all the functions of the MultiGrid with a system against islanding and a long list of certifications for many countries that continues to grow.
Note: For a while, this product was called MultiGrid-II.

More details

More info

Victron

 

New 48V converter/charger


A MultiPlus-II with LCD screen and GX functionality


The MultiPlus-II GX incorporates a MultiPlus-II converter/charger and a GX device with a 2 x 16 character display.


Screen and Wi-Fi


The screen reads the settings of the solar charge controller, battery and converter.
The same settings can be accessed from a smartphone or device with a Bluetooth function enabled.


GX device


The integrated GX device includes:
• BMS-Can interface. It can be used to connect to a compatible can-bus-managed battery. Note that this is not an EV-compatible port. CAN.
• One USB port.
• One Ethernet port.
• One EV port. Direct.


Applications


The MultiPlus-II GX is intended for applications that require additional interfacing with other products and/or remote monitoring, such as on-grid or off-grid energy storage systems and certain mobile applications.


Parallel or three-phase operation


Only one GX unit is required for parallel or three-phase operation


Standard, mobile or off-grid marine application


Loads that need to be turned off when AC input power is not available can be connected to a second (not off) output. These loads will be taken into account by the PowerControl and PowerAssist functions in order to limit the AC input current according to a safe value if AC power is available.

Schéma Application marine standard, mobile ou hors-réseau


Standard or off-grid mobile app with an external current probe


Maximum current detection range: 50 A and 100 A, respectively.

Schéma Application mobile standard ou hors réseau avec une sonde de courant externe


Grid parallel topology with MPPT solar charge controller


The MultiPlus-II will use data from the AC current probe (to be ordered separately) or the power meter to optimize self-consumption and, if necessary, avoid energy returns to the grid. In the event of a power outage, the MultiPlus-II will continue to power critical loads.

Schéma: Topologie parallèle au réseau avec le contrôleur de charge solaire MPPT


Online topology on the network with a PV converter


PV energy is directly converted into AC.
The MultiPlus-II will use excess PV power to charge batteries or return energy to the grid, and it will discharge batteries or use grid energy in case of a lack of PV power. In the event of a power outage, the MultiPlus-II will disconnect from the grid and continue to power the loads.

 

Schéma: Topologie en ligne sur le réseau avec un convertisseur PV


 Characteristics

 

MultiPlus-II GX48/3000/35-32
48/5000/70-50
PowerControl / PowerAssistYes
Transfer switch32 A50 A
Maximum AC input current32 A50 A
Auxiliary outputYes (32 A)
CONVERTER
DC supply voltage range19 – 33V38 – 66 V
ExitOutput voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0.1% (1)
Continuous output power at 25°C3000 VA5000 VA
Continuous output power at 25°C2400 W4000 W
Continuous output power at 40°C2200 W3700 W
Continuous output power at 65°C1700 W3000 W
Then. of maximum return. Alleged3000 VA5000 VA
Peak power5500 W9000 W
Maximum efficiency95 %96%
Unladen consumption11 W18 W
Unladen power consumption in AES mode7 W12 W
Zero charging power in Search mode2 W
CHARGER
AC inputSupply voltage range: 187-265 VAC Input frequency: 45 – 65 Hz
"Absorption" charging voltage57.6 V
Charging voltage "Float"55.2 V
Storage mode52.8 V
Maximum battery charging current35 A70 A
Battery temperature probeYes
GENERAL
InterfacesBMS-Can, USB, Ethernet, VE. Direct, Wi-Fi
External current probe AC (optional)50 A100A
Programmable relayYes
Protectiona - g
EV communication port. BusFor parallel or three-phase operation, remote control and system integration
Universal com. portYes, 2x
Remote on/offYes
Operating temperature range40 to +65°C (fan cooling)
Humidity (non-condensing)max 95%
CASE
Material and colorSteel, blue RAL 5012
Degree of protectionIP22
Battery connectionM8 bolts
230 VAC connectionScrew terminals 13 mm² (6 AWG)
Weight19 kg30 kg
Dimensions (H x W x D) mm506 x 275 x 147565 x 323 x 148
Standards
SecurityEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, ImmunityEN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Data sheets and documentation

Specifications

Inverter power- de 1000VA