SMA Sunny Island SI4.4M-13/SI6.0H-13/SI8.0H-13
More info
Even more economical
With the new generation of devices, the installation of the proven Sunny Island charger inverter is even simpler and more economical. Whether in your own home or for industrial applications. On the public power grid or in areas far from the grid.
The Sunny Island has already been installed more than 120,000 times worldwide. With the new generation, installers and plant operators benefit from an even more user-friendly charger inverter.
• Lower system costs due to fewer components
• Faster installation and commissioning with a simple user interface
• Extended warranty period: 10 years
Flexible implementation in residential and business
The Sunny Island is particularly flexible, whether it is used in remote areas of the grid or for energy management in the private or industrial field. It offers planners maximum freedom in terms of system size and type, battery and energy production mode. For self-consumption systems, emergency power supply and networks in isolated sites.
• Possibility of subsequent equipment and modular expansion for single-phase and three-phase systems from 1 to 30 kilowatts
• For all lead-acid batteries and more than 20 different lithium-ion batteries
• Scalable with SMA's multi-cluster technology for systems from 20 to 300 kilowatts
Reliable energy supply at all times
• The Sunny Island operates reliably even in the most extreme conditions, without loss of profitability.
• Extremely high overload capacity ensures energy supply even in critical situations
• IP54 for operation even in extreme conditions
Characteristics
Models | Sunny Island 4.4M | Sunny Island 6.0H | Sunny Island 8.0H |
Operation with public network or generator | |||
Rated Network Voltage / AC Voltage Range | 230 V / 172.5 V to 264.5 V | ||
Assigned network frequency / authorized frequency range | 50 Hz / 40 Hz to 70 Hz | ||
Maximum alternating current for self-consumption optimization (network management) | 14.5 A | 20 A | 26 A6) |
Maximum AC effective power for self-consumption optimization (network management) | 3.3 kVA | 4.6 kVA | 6 kVA6) |
Maximum AC input current | 50 A | ||
Maximum AC input power | 11500 W | ||
Adjustable phase shift factor | 0.8 inductive to 0.8 capacitive | ||
Isolated site operating mode or backup mode | |||
Rated Network Voltage / AC Voltage Range | 230 V / 202 V to 253 V | ||
Rated Frequency / Frequency Range (Adjustable) | 50 Hz/45 Hz to 65 Hz | ||
Rated power (for Unom, fnom / 25 °C / cos φ = 1) | 3300 W | 4600 W | 6000 W |
AC power at 25 °C for 30 min / 5 min / 3 s | 4400 W / 4600 W / 5500 W | W 6000 W / 6800 W / 11000 W | 8000 W / 9100 W / 11000 W |
AC power at 45°C | 3000 W | 3700 W | 5430 W |
Rated Current / Maximum Output Current (Peak) | 14.5 A / 60 A | 20 A / 120 A | 26 A / 120 A |
Harmonic distortion rate output voltage / Power factor at rated power | < 5% / −1 to +1 | < 1.5% / −1 to +1 | < 1.5% / −1 to +1 |
DC battery input | |||
Rated Input Voltage / DC Voltage Range | 48 V / 41 V to 63 V | ||
Maximum battery charge current / DC rated charging current / DC rated discharge current DC | 75 A / 63 A /75 A | 110 A/90 A/103 A | 140 A / 115 A /130 A |
Battery Type / Battery Capacity (Range | Li-Ion1), FLA, VRLA / 100 Ah to 10000 Ah (lead) 50 Ah to 10000 Ah (Li-Ion) | ||
Load control | IUoU charging method with full load and automatic equalization load | ||
Efficiency / Self-consumption of the device | |||
Maximum yield | 95,5 % | 95,8 % | 95,8 % |
Open circuit power consumption / Standby mode | 18 W / 6.8 W | 25.8 W / 6.5 W | 25.8 W / 6.5 W |
Protective device (apparatus) | |||
AC Short Circuit / AC Overload | ● / ● | ||
DC Reverse Polarity Protection / DC Fuse | − / − | ||
Overtemperature / Excessive battery discharge | ● / ● | ||
Overvoltage category according to IEC 60664-1 | III | ||
General characteristics | |||
Dimensions (W/H/D) | 467 mm / 612 mm / 242 mm (18.4 inches / 21.1 inches / 9.5 inches) | ||
Weight | 44 kg (97 lb) | 63 kg (138.9 lb) | 63 kg (138.9 lb) |
Operating temperature range | −25 °C to +60 °C (−13 °F to +140 °F) | ||
Protection class according to IEC 62103 | I | ||
Climate class according to IEC 60721 | 3K6 | ||
Protection rating according to IEC 60529 | IP54 | ||
In accordance with RoHS-III | ● | ||
Equipment / Function | |||
Micro SD memory card for extended data recording | ○ | ||
Three-phase systems (with rotating field)2) / Emergency current function | ● / ● | ||
Calculation of state of charge / Full load / EQ load | ● / ● / ● | ||
Battery Temperature Sensor / Communication Cables | ○ / ● | ||
Certificates and approvals | www/SMA-France.com | ||
Yellow lid color / white aluminum | ○ / ○ | ||
Warranty: 5 / 10 years | ● / ●³) | ||
For isolated site installations | |||
Switching time in backup mode (without switching or MC-Box)4) | − | 0 ms (high ohmic value) / 20 ms (their ohmic value) | |
Automatic rotating field detection / generator support | ● / ● | ||
Parallel Mounting / Multicluster | − / − | ● / ● | ● / ● |
Integrated soft start | ● |
● Standard equipment ○ Optional equipment — Not available; All specifications – version: 09/2020
1) See "List of Approved Batteries" on www.SMA-Solar.com 2) 3 x Sunny Island 3) When registering in Sunny Portal 4) See "Switchovertime-TI-en-11 | Version 1.1 » on www.SMA-Solar.com
5) Procurement through an external supplier 6) different limitation depending on the parameterized regional dataset (e.g. VDE-AR-N 4105:2018= 4.6 kVA and 20 A)