IP 65 three-phase hybrid solar converter supporting 150% imbalance load.
With IP65 protection, the Multisolart F16 is suitable for outdoor applications and indoor environments where atmospheric moisture and dust are present. It supports a load imbalance of 150% and the maximum load can reach 15kW for each phase. This flexibility can facilitate different energy consumption in a home environment. With the built-in AC coupling function, the existing system on the network can be easily upgraded and extended to a hybrid system. The Multisolar F16 30Kw also offers a second terminal for user choice as generator input or programmable output.
• Water and dust tightness (IP65) makes the inverter available for various working conditions.
• Support for 150% of unbalanced load
• Dual output for intelligent load management
• Integrated AC paired function
• Built-in WiFi for mobile monitoring (an app is available)
• User adjustable charging current up to 50A
• Wide range of battery inputs
• Integrated communication port for BMS (RS485)
• Parallel operation of up to 4 units
Characteristics
Model | Multisolar F16 30kW |
Maximum PV input power | 40000W |
Rated output power | 30000W |
Maximum charging power | 18000W |
Networking | |
PV input (DC) | |
Nominal DC Voltage / Maximum DC Voltage | 720VDC / 1000 VDC |
Starting voltage / Initial supply voltage | 320 VDC / 350 VDC |
MPP voltage range | 350 VDC ~ 900 VDC |
Number of MPP trackers / Maximum input current | 3/A: 26A, B:26A, C: 26A |
Number of strings per MPP tracker | A:2, B:2, C:2 |
NETWORK OUTPUT/UTILITY (AC) | |
Nominal output voltage | 230VAC (P-N) / 400 VAC (P-P) |
Output voltage range | 184-265 VAC per phase |
Nominal output current | 43.5 A per phase |
Power factor | 0.9 lag to 0.9 lead |
EFFICIENCY | |
Maximum conversion efficiency (DC/AC) | 96.5% |
Vnominal européen@ yield | 96% |
OFF-GRID OPERATION | |
AC INPUT | |
AC Start Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC per phase |
Acceptable input voltage range | 170 - 280 VAC per phase |
Maximum AC input current | 50A |
PV INPUT (DC) | |
Maximum DC voltage | 1000 VDC |
MPP voltage range | 350 VDC ~ 900 VDC |
Number of MPP trackers / Maximum input current | 3 / A: 26A, B: 26A, C: 26A |
OUTPUT IN BATTERY MODE (AC) | |
Nominal output voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output waveform | Pure sine wave |
Performance (CD to HQ) | 96% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Maximum DC voltage | 1000 VDC |
Starting voltage / Initial supply voltage | 320 VDC / 350 VDC |
MPP voltage range | 350 VDC ~ 900 VDC |
Number of MPP trackers / Maximum input current | 3 / A: 26A, B: 26A, C: 26A |
NETWORK OUTPUT (AC) | |
Nominal output voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output voltage range | 184 - 265 VAC per phase |
Nominal output current | 43.5 A per phase |
AC INPUT | |
AC Start Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC per phase |
Acceptable input voltage range | 170 - 280 VAC per phase |
Maximum AC input current | 50A |
OUTPUT IN BATTERY MODE (AC) | |
Nominal output voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Performance (CD to AC) | 96% |
BATTERY AND CHARGER | |
Battery voltage range | 600~1000 VDC |
Maximum charging current | 30 A |
GENERAL | |
PHYSICS | |
Dimensions, D x W x H (mm) | 255 x 660 x 750 |
Net weight (kgs) | 73 |
INTERFACE | |
Communication port | RS-232, USB, DRY CONTACT, RS-485 and Wi-Fi |
Smart slot | Optional SNMP, MODBUS and GPRS |
ENVIRONMENT | |
Humidity | 0~100% RH |
Operating temperature | -From -25°C to 60°C (downgrading >45°C) |
Altitude | 0~1000 m** |
*These figures are based on VDE-4105. All figures may vary depending on AC voltage and country requirements. ** Power downgrade of 1% every 100 m when altitude is above 1000m. Product specifications are subject to change without notice. |
SoftWare1.17SP7
Data sheets and documentation
Specifications
73 Kg | |
Triphasé | |
2 MPPT | |
660 mm | |
750 mm | |
255 mm |