Hybrid inverter 30kW network injection - storage Multisolar F16

Wattuneed

More info

Présentation onduleur Multisolar F16 - 30kW

 

IP 65 three-phase hybrid solar converter supporting 150% imbalance load.

With IP65 protection, the Multisolart F16 is suitable for outdoor applications and indoor environments where atmospheric moisture and dust are present. It supports a load imbalance of 150% and the maximum load can reach 15kW for each phase. This flexibility can facilitate different energy consumption in a home environment. With the built-in AC coupling function, the existing system on the network can be easily upgraded and extended to a hybrid system. The Multisolar F16 30Kw also offers a second terminal for user choice as generator input or programmable output.

 

• Water and dust tightness (IP65) makes the inverter available for various working conditions.
• Support for 150% of unbalanced load
• Dual output for intelligent load management
• Integrated AC paired function
• Built-in WiFi for mobile monitoring (an app is available)
• User adjustable charging current up to 50A
• Wide range of battery inputs
• Integrated communication port for BMS (RS485)
• Parallel operation of up to 4 units


Characteristics

 

ModelMultisolar F16 30kW
Maximum PV input power40000W
Rated output power30000W
Maximum charging power18000W
Networking
PV input (DC)
Nominal DC Voltage / Maximum DC Voltage720VDC / 1000 VDC
Starting voltage / Initial supply voltage320 VDC / 350 VDC
MPP voltage range350 VDC ~ 900 VDC
Number of MPP trackers / Maximum input current3/A: 26A, B:26A, C: 26A
Number of strings per MPP trackerA:2, B:2, C:2
NETWORK OUTPUT/UTILITY (AC)
Nominal output voltage230VAC (P-N) / 400 VAC (P-P)
Output voltage range184-265 VAC per phase
Nominal output current43.5 A per phase
Power factor0.9 lag to 0.9 lead
EFFICIENCY
Maximum conversion efficiency (DC/AC)96.5%
Vnominal européen@ yield96%
OFF-GRID OPERATION
AC INPUT
AC Start Voltage / Auto Restart Voltage120 - 140 VAC / 180 VAC per phase
Acceptable input voltage range170 - 280 VAC per phase
Maximum AC input current50A
PV INPUT (DC)
Maximum DC voltage1000 VDC
MPP voltage range350 VDC ~ 900 VDC
Number of MPP trackers / Maximum input current3 / A: 26A, B: 26A, C: 26A
OUTPUT IN BATTERY MODE (AC)
Nominal output voltage230 VAC (P-N) / 400 VAC (P-P)
Output waveformPure sine wave
Performance (CD to HQ)96%
HYBRID OPERATION
PV INPUT (DC)
Maximum DC voltage1000 VDC
Starting voltage / Initial supply voltage320 VDC / 350 VDC
MPP voltage range350 VDC ~ 900 VDC
Number of MPP trackers / Maximum input current3 / A: 26A, B: 26A, C: 26A
NETWORK OUTPUT (AC)
Nominal output voltage230 VAC (P-N) / 400 VAC (P-P)
Output voltage range184 - 265 VAC per phase
Nominal output current43.5 A per phase
AC INPUT
AC Start Voltage / Auto Restart Voltage120 - 140 VAC / 180 VAC per phase
Acceptable input voltage range170 - 280 VAC per phase
Maximum AC input current50A
OUTPUT IN BATTERY MODE (AC)
Nominal output voltage230 VAC (P-N) / 400 VAC (P-P)
Performance (CD to AC)96%
BATTERY AND CHARGER
Battery voltage range600~1000 VDC
Maximum charging current30 A
GENERAL
PHYSICS
Dimensions, D x W x H (mm)255 x 660 x 750
Net weight (kgs)73
INTERFACE
Communication portRS-232, USB, DRY CONTACT, RS-485 and Wi-Fi
Smart slotOptional SNMP, MODBUS and GPRS
ENVIRONMENT
Humidity0~100% RH
Operating temperature-From -25°C to 60°C (downgrading >45°C)
Altitude0~1000 m**
*These figures are based on VDE-4105. All figures may vary depending on AC voltage and country requirements.
** Power downgrade of 1% every 100 m when altitude is above 1000m.
Product specifications are subject to change without notice.

 

SoftWare1.17SP7

Data sheets and documentation

Specifications

Weight73 Kg
Monophasé / TriphaséTriphasé
Nombre de MPPT2 MPPT
Width660 mm
Height750 mm
Thickness255 mm