Onduleur hybride 3kW - injection réseau - stockage. Augmentez votre autoconsommation 

 

High efficiency

  • Accurate real-time MPPT algorithm for maximum power generation
  • Wide operating range of the input voltage
  • Independent MPPT double tracking, flexible solar roof system design.

 

Reliable and safe

  • High efficiency, low energy loss, low maintenance
  • High frequency isolation between battery and PV network
  • Advanced battery management technology to protect battery life

 

Easier operation

  • Free choice of site thanks to the IP65
  • Clear and easy-to-read 4' LCD screen
  • Easy monitoring on phone (APP) and PC (web)

 

Multiple modes of operation

  • PV and all-in-one storage, increases self-consumption to more than 80%, decreases dependence on the electricity grid and reduces the electricity bill.
  • Autonomous mode (like UPS) available, ensures safe operation of critical loads.
  • Selection of several operating modes: automatic mode, usage time mode, timeout mode, passive mode, etc.

 

Intelligent network management

  • Reactive power capacity
  • Limits AC output when the network frequency is too high or too low.
  • Limits AC output when the network voltage is too high.
  • Built-in zero export function (optional)

Store your solar production

 

Stockez votre production solaire

 


Easy installation

 

Schéma de branchement de l'onduleur


Characteristics

 

ModelWKS I3WKS I3.6WKS I4WKS I5WKS I6
Battery settings
Battery typeLead-acid, Lithium-ion
Rated battery voltage48V
Battery voltage range42-58V
Minimum discharge voltageLithium: (according to BMS), Max 58V
Acid lead: 44.0V
Maximum charging voltageLithium-ion (according to BMS), Max 58V
Acid lead: 58V
Recommended battery200Ah (100-500 Ah optional)
Recommended storage9.6 kWh
Max charging current60A
Charging current range0-65A programmable
Load curve3-stage adaptive with maintenance
Maximum discharge current0-70A programmable
Battery protectionSurge protection / Overcurrent protection / Overheat protection
Depth of dischargeLithium: 0-80% adjustable DOD
Acid lead:0-50% adjustable DOD
PV settings
Maximum input power3500W4790W4400W5500W6600W
Max DC power supply for single MPPT2000W2400W2600W3000W3500W
The input voltage DC max.600V
Boot DC voltage120V
Rated DC voltage360V
MPPT working voltage90-580V
DC voltage range at full load160V-520V180V-520V200V-520V300V-520V
Number of MPPT2
The input current DC max.12A/12A
The short circuit of the DC input max.15A/15A
AC settings
Max output power3000W3600W4000W5000W6000W
Max output current13.7A16A18.2A22.8A27.3A
Nominal network voltage and frequency220V, 230V, 240V, 44-55Hz or 54-66Hz
AC voltage range180-2876V (as required by local authorities)
THD<3%
Power factor1 default (+/-0.8 adjustable)
In-call current0.8A/1us
Max output fault current.100A/1us
System Settings
Maximum efficiencyCharge:94.1% / discharge 94.3%
Pending losses<5W (PV SPS)
TopologyHigh frequency insulation
Intrusion Protection RatingsIP 65
Security protectionAnti-islanding, RCMU, ground fault monitoring
CommunicationWi-Fi/GPRS, RS485, SD, CAN2.0
Environmental data
Room temperature30°C + 60°C (Downgrading above +45°C)
Relative humidity range0% - 100% (non-condensing)
Protection classClass I
Maximum operating altitude2000m
Connecting the current transformerWired
General data
Noise<25 dB
Weight20.5 kg
CoolingNatural convection
Dimensions (L*H*P)566x394x173 mm
Display screenLCD
Guarantee5 years or more
EPS (Emergency Power Supply) data
Rated EPS power3000VA
Rated EPS voltage/frequency230V,50/60Hz
Rated current EPS13A
THD<3%
Switching time10 mS by default

Specifications

Inverter power3600 VA

Accessories