SolarEdge's Power Optimizer is a DC/DC converter that connects to each solar module in a PV system, and turns them into smart modules. By constantly tracking the maximum power point (MPP) of each individual solar module, Power Optimizers increase the system's energy production, which can increase revenue and accelerate the system's return on investment.
By attaching our power optimizers to each solar module, installers, electricians and operations and maintenance personnel can easily monitor system performance and locate and resolve problems at any point in the chain with extreme precision.
Each Power Optimizer is equipped with industry-leading safety mechanisms, such as the unique SafeDCTM feature designed to automatically reduce the high DC voltage of the modules to a safe level when the UPS or power grid is shut down, for maximum protection of people and property.
Overview of the S Series Home Power Optimizer
SolarEdge has launched its most innovative residential power optimizer.
The S Series further strengthens our industry-leading security technology, setting a new benchmark for arc-flash detection and prevention with the SolarEdge Sense Connect feature (available from 2022 via a firmware update).
We have also streamlined our range of Power Optimizers to simplify project design and logistics, shorten installation times with improved cable layout, and evolve each S Series model to meet changing PV module requirements.
Flexible design with module-level MPPT
The tracking of the maximum power point at the module level allows more flexibility in the design, especially for installations with several orientations, inclinations and types of modules on the same line. When working with SolarEdge inverters, each Power Optimizer automatically maintains a fixed string voltage, giving installers even more flexibility with longer chains and chains of different lengths to design optimal PV systems.
SolarEdge power optimizers are compatible with all module types, including high-power modules and bifacial modules.
Key benefits
• Maximum Power Point (MPPT) tracking per module, with one power optimizer for two modules supported by tertiary power optimizers.
• Superior efficiency (peak efficiency 99.5%, weighted efficiency 98.8%)
• Mitigates all energy losses related to mismatch between modules, from manufacturing tolerance to partial shading and aging.
• Compatible with all module types, including high power modules and bifacial modules
• Accurate and real-time monitoring of module performance
• Industry-leading built-in security features for maximum protection of people and property:
• SafeDC,™ designed to automatically reduce DC voltage to a safe level in the event of a grid or UPS downtime
• Sense Connect SoalrEdge, for proactive monitoring and detection of faulty wiring that could cause connectors or arcing to overheat*.
• Designed for extreme environmental conditions
• 25-year warranty on the product
• Available pre-framed mount for faster installation
*For S-Series Power Optimizers only, available from 2022 via firmware update
Characteristics
Model | S500 | S440 | Unit |
Rated DC input power(1) | 500 | 440 | W |
Maximum absolute input voltage (VoC) | 60 | 60 | Vdc |
MPPT Operating Range | 8-60 | 8-60 | Vdc |
Maximum short-circuit current (Isc) of the connected PV module | 15 | 14.5 | Adc |
Maximum yield | 99.5 | 99.5 | % |
Weighted return | 98.6 | 98.6 | % |
Surge category | II | II | |
OUTPUT IN OPERATION | |||
Maximum output current | 15 | 15 | Adc |
Maximum output voltage | 60 | 60 | Vdc |
STANDBY OUTPUT (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) | |||
Safety output voltage by power optimizer | 1 | 1 | Vdc |
COMPLIANCE | |||
EMC | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 | FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 | |
Security | IEC62109-1 (Class II Safety), UL1741 | IEC62109-1 (Class II Safety), UL1741 | |
Material | UL94 V-0, UV resistant | UL94 V-0, UV resistant | |
RoHS | Yes | Yes | |
Fire safety | VDE-AR-E 2100-712:2013-05 | VDE-AR-E 2100-712:2013-05 | |
INSTALLATION SPECIFICATIONS | |||
Maximum allowable system voltage | 1000 | 1000 | Vdc |
Dimensions (W x D x H) | 129 x 155 x 30 | 129 x 155 x 30 | mm |
Weight (including cables) | 655 | 655 | gr |
Input connector | MC4(2) | MC4(2) | |
Input cable length | 0,1 | 0,1 | m |
Output connector | MC4 | MC4 | |
Output cable length | (+) 2,3, (-) 0,10 | (+) 2,3, (-) 0,10 | m |
Operating temperature range(3) | 40 to +85 | 40 to +85 | °C |
Protection factor | IP68 / NEMA6P | IP68 / NEMA6P | |
Relative humidity | 0 - 100 | 0 - 100 | % |
(1) The STC rated power of the module will not exceed the rated input DC power of the power optimizer. Modules with a power tolerance of up to +5% are allowed (2) For other connector types, please contact SolarEdge (3) For an ambient temperature above +70 °C, a power reduction shall be applied. Refer to Technical Note on Power Optimizer Power Reduction Due to temperature for details. |