
Hybrid inverter 15kW injection network - Multisolar storage
More info
MultiSolar: Store the bare minimum in your batteries and re-inject the bare minimum into the network, provided the batteries are full.
On the other hand, use the network to fill the gap winter production and make a little extra on the batteries when the rainy days follow.
Make the most of your production and no longer fear any power outages.
Plug in until 14850Wc at the PV entrance of the 'linkpopup id'onduleurHybride'
Store and use your solar-generated electricity later.
description
High-performance MultiSolar inverter -linkpopup id'triphase' to manage a hybrid electrical installation.
Connect solar panels, batteries, and optional network input to power your facility
Enjoy the best performance with two built-in independent 'linkpopup id'mppt' trackers, as well as a comfortable use of its compact design and intuitive LCD screen.
- Pure sinusoidal signal output: 10kW
- Maximum PV input power: 14850Wc
- AC Entry: 'linkpopup id'triphase'
- AC release: 'linkpopup id'triphase'
- Controlled by microprocessor for stability
- Multiple operations: Connected to the network, off-grid and connected to the network with backup power
- Built-in solair charger (two independent inputs)
- Backlit LCD screen for simple, interactive use
- Multiple means of communication
- "Green" alternative to generators
- User-adjusted battery charge intensity, up to 200A
Remote control and inverter configuration
Connect the inverter to your computer with the USB cable provided.
SolarPower software allows the control and tracking of multiple devices via the local network, internet or USB.
Alert notifications, pop-up screen, text messages and email.
Software
SoftWare1.17SP7
Characteristics
phase 3 phase in / 3 phase out Max PV power 22500 W Power on the way out 15000 W Max charge power 15000 W Network-connected operation Solar Entrance (DC) Rated DC Tension / Maximum DC Tension. 720 VDC / 900 VDC Start-up tension / Work min tension 320 VDC / 350 VDC MPP voltage range 400 VDC - 800 VDC Entry number MPP/maximum current input 2/A: 37.65A; B:18.6A Consumer output (AC) Nominal output voltage 230 VAC (N-P)/400 VAC (P-P) Exit voltage range 184 - 264.5 VAC per phase Nominal output current 21.7 A per phase Power factor > 0.99 yield Maximum conversion return (DC/AC) 96,00% European performance at the tension 95,00% Off-grid AC Entry AC start voltage /automatic restart voltage 120 - 140 VAC per phase
180 VAC per phaseEntry voltage range 170 - 280 VAC per phase AC max input current. 40 A Solar Entrance (DC) Tension DC max. 900 VDC MPP voltage range 350 VDC - 850 VDC Entry number MPP/maximum current input 2/A: 37.65A; B:18.6A Battery mode (AC) release Nominal output voltage 230 VAC (N-P)/400 VAC (P-P) Signal shape Pure sinus yield (DC/AC) 91,00% Hybrid operation Solar Entrance (DC) Rated DC Tension / Maximum DC Tension. 720 VDC / 900 VDC Start-up tension / Work min tension 320 VDC / 350 VDC MPP voltage range 350 VDC - 850 VDC Entry number MPP/maximum current input 2/A: 37.65A; B:18.6A Consumer output (AC) Nominal output voltage 230 VAC (N-P)/400 VAC (P-P) MPP voltage range 184 - 264.5 VAC per phase Nominal output current 21.7 A per phase AC Entry Start-up tension / Work min tension 120 - 140 VAC per phase
180 VAC per phaseEntry voltage range 170 - 280 VAC per phase AC max input current. 40 A Battery mode (AC) release Nominal output voltage 230 VAC (N-P)/400 VAC (P-P) yield (DC/AC) 91,00% Batteries and charger Nominal DC tension 48 VDC Max charge current. Default 60A, 5A -300A (adjustable) General features Physical characteristics Dimensions P x L x H 219 x 650 x 820 mm weight 62 Kg interface Communication port RS-232 / USB and CAN Interface Intelligent Slot Optional SNMP, Modbus and AS-400 cards environment 0 - 90% HR (without condensation) humidity -10 to 55 degrees Celsius Working temperature 0 - 1000m
Data sheets and documentation
Specifications
62 kg | |
Triphasé | |
2 MPPT | |
500 mm | |
622 mm | |
176 mm | |
15000VA |