SMA Sunny Tripower Core1 STP50-40
More info
The Sunny Tripower CORE1 is the first freestanding string inverter. This new design allows for simpler and faster installation without a support system
INSTALLATION ON LARGE ROOFS UP TO 60% FASTER
The first self-supporting string inverter for photovoltaic installations on large roofs, on the ground or parking canopies, the Sunny Tripower stands out for its innovative design. As a result, installation is up to 60% faster and costs are reduced.
TURN YOUR PROJECTS INTO SUCCESS
The third generation of the globally successful Sunny Tripower inverter range, the Sunny Tripower CORE1 revolutionizes the segment of inverters for photovoltaic installations on large roofs. The Sunny Tripower combines a unique design and an innovative installation concept that significantly reduces installation time. You benefit from an optimal return on investment.
FLEXIBILITY FOR MAXIMUM ENERGY PRODUCTION
- Maximum scalability for your projects up to several megawatts
- Unique design for an oversizing of the photovoltaic array by up to 150%.
- 6 MPP trackers for optimal energy production
INTELLIGENTLY INTEGRATED
- Fully integrated design ensures reduced costs for BoS components, logistics and materials
- In addition to the 12 direct string inputs, the CORE1 features a DC disconnector and, optionally, an AC and DC surge protection device.
PROFITABLE
- No additional mounting device
- Simple substructure for some commercial applications
- Additional savings due to reduced fieldwork, time and equipment
OPTICOOL™ ACTIVE COOLING SYSTEM
- Ensures reliable operation and maximum energy production
- Secure photovoltaic investment
- Reduced Service expenses thanks to proven technology and an installed base of more than 50 GW worldwide
A COMPACT AND POWERFUL INVERTER FOR INSTALLATIONS ON LARGE ROOFS, ON THE GROUND AND PARKING SHADES
The versatile solution with optimal return on investment - From distribution to construction to operation. The Sunny Tripower CORE1 enables reductions in logistics, material, professional and service costs.
Achieve additional savings...
THE BENEFITS FOR DISTRIBUTORS
- Various applications possible with a single product
- An international platform for universal use
- A small number of BoS parts and components
- Optimal support and service
Reduce procurement and installation costs ...
BENEFITS FOR EPCS AND DEVELOPERS
- Plug and play installation concept
- Reduced material costs
- Faster installation and less work
- Free tool for sizing the installation
Description
Specifications | Sunny Tripower CORE1 |
Input (DC) | |
Max. power of the photovoltaic generator | 75000 Wp STC |
Max input voltage | 1000 V |
MPP voltage range / input voltage Assigned | 500 V to 800 V / 670 V |
Min. input voltage / input voltage of startup | 150 V / 188 V |
Max. input current / per MPPT | 120 A / 20 A |
Max. short-circuit current per MPP tracker/ per string entry | 30 A / 30 A |
Number of independent MPPT inputs / strings per MPPT input | 06/02/19 |
Output (AC) | |
Rated power (for 230 V, 50 Hz) | 50000 W |
Apparent power AC max | 50000 VA |
Rated AC voltage | 220 V / 380 V 230 V / 400 V 240 V / 415 V |
AC voltage range | 202 to 305 V |
AC/Range Network Frequency | 50 Hz / 44 Hz to 55 Hz 60 Hz / 54 Hz to 65 Hz |
Rated network frequency/voltage assigned network | 50 Hz / 230 V |
Max Output Current/Rated Output Current | 72.5 A / 72.5 A |
Injection phases/AC connection | 3 / 3-(N)-PE |
Power factor at rated power/ Adjustable phase shift factor | 1 / 0 inductive to 0 capacitive |
THD | <3% |
Protective devices | |
DC side disconnection device | ● |
Ground Fault Monitoring/Monitoring of the network | ● / ● |
DC/resistor reverse polarity protection AC short circuit/galvanic separation | ● / ● / — |
Fault current monitoring unit, Sensitive to all currents | ● |
Protection class (according to IEC 62109-1)/ Overvoltage category (according to 62109-1) | I/AC: III; DC: II |
Type II AC/DC surge protector | ○ / ○ |
Yield | |
Max./European yield | 98,1 % / 97,8 % |
General characteristics | |
Dimensions (W/H/D) | 621 mm / 733 mm / 569 mm (24.4 in / 28.8 in / 22.4 in) |
Weight | 84 kg (185 lb) |
Operating temperature range | u201225°C to +60°C (u201213°F to +140°F) |
Noise emissions (typical) | <65 dB(A) |
Self-consumption (night) | 4.8 W |
Topology/cooling system | Transformerless / OptiCool |
Protection class (according to IEC 60529) | IP65 |
Climate class (according to IEC 60721-3-4) | 4K4H |
Maximum permissible value of relative humidity of air (non-condensing) | 100,00% |
Equipment/Function/Accessories | |
DC Connection/AC Connection | SUNCLIX/Screw terminal |
Support feet | ● |
LED display (status/error/communication) | ● |
Multifunction Relay/Ports for Modules Extension | ● / ● (2 entries) |
OptiTrack Global Peak/Integrated Plant Control/Q on Demand 24/7 | ● / ● / ● |
Off-grid/SMA Fuel compatible Save Controller | ● / ● |
Warranty: 5/10/15/20 years | ● / ○ / ○ / ○ |
Certifications and approvals (other on request) * Not valid for all national annexes to EN 50438 | ANRE 30, AS 4777, BDEW 2008, C10/11:2012, EC, IEC 0-16, IEC 0-21, EN 50438:2013*, G59/3, IEC 60068-2-x, IEC 61727, IEC 62109-1/2, IEC 62116, MEA 2016, NBR 16149, NEN EN 50438, NRS 097-2-1, AEP 2016, PPC, RD 1699/413, RD 661/2007, Res. n°7:2013, SI4777, TOR D4, TR 3.2.2, UTE C15-712-1, VDE 0126-1-1, VDE-RNA 4105, VFR 2014, P.O.12.3, NTCO-NTCyS, GC 8.9H, PR20, DEWA |
● Standard equipment ○ Optional equipment — Not available Data in nominal conditions - version: 07/2017 | |
Type designation | STP 50-40 |
Data sheets and documentation
Specifications
1000 V | |
84 Kg | |
50000 VA | |
Triphasé | |
621 mm | |
733 mm | |
569 mm | |
5000VA |