More info
The EVO WKS is designed with a transfer time zero
- Transfer time to protect critical loads such as the servers and the ATMs.
- Removable LCD control module with several communications port: dry contact, micro-USB, RS-232
- Integrated Bluetooth for monitoring mobile (Android App is available)
- Supports the feature USB On-the-Go
- Communication port reserved for BMS (RS485, CAN BUS or RS232)
- Use of AC output timer / configurable PV and prioritization
- Optional parallel operation up to 9 units: 3 x 3 units in parallel to a facility up to 45 kVA single-phase or three-phase.
Communication Bluetooth (WatchPower)
Set up your UPS and your installation, check your production and save your data from your smartphone!
The Bluetooth of the Evo WKS application easily gives you access to all the information of your installation.
The inverter generation
Enjoy a continuous and reliable supply that the network is available or not. The energy produced by the inverters WKS is oriented and used intelligently for optimal performance. All priorities can be defined by the user: use of batteries, solar or the AC source (generator or network). Consumption, energy produced by your panels is fluctueuse and it does not match the consumption. The inverter WKS stock part of the solar production in batteries for later use during the evening or night. In remote areas, the WKS inverter can be connected to a generator to ensure the charge of the batteries if they are empty and the solar production is insufficient. This inverter is able to work with several different energy sources such as:
- public network
- photovoltaic panels
- thermal generator
- batteries
Management by microprocessor directs energy based on production, consumption needs and the State of charge of the batteries. It is possible to carry out a follow-up in real-time locally or remotely. Inverter WKS feeding power into the grid.
3 operating modes
- Solar priority
- Relief
- Solar and network
Power multi-energie
Example: for a need in consumption of 3kW, you can have a configuration:
- 1 kW provided by solar energy
- 2 kW provided by batteries
This technique of multi power allows to strongly decrease the Battery Park and extend its life.
This inverter accepts up to 1500 W of photovoltaic panels and can connect to the network or another source of renewable energy if the solar production is insufficient.
Applications:
- Residential, commercial and telecommunications
- Areas where electricity supply is unstable
- Areas that are not connected to the network
Use back-up mode
It is possible to use the ups as a "back-up", without solar panels. In this mode, the UPS will ensure the role of UPS to protect your devices from the network cuts.
The UPS protects computers and equipment audio-visual or any other sensitive charge by providing a stable current. It guarantees a power supply of consumers.
The electricity produced from these inverter pure sine is stable.
Possibility to protect one or more rooms in your home through the distribution box.
Use in Off-grid mode (off-grid)
In this configuration, the inverter uses panels to supply consumers and to charge the batteries when the Sun is present. The inverter draws aware of batteries to ensure the distribution of energy at night.
There is possibility to add a generator on the inverter AC input to ensure a backup power supply.
Use in mode hybrid
The inverter takes power on the network only if the batteries are empty and that the solar production was not sufficient to cover the consumption.
The inverter back never power on the grid.
As for the "back-up" mode, it is possible to connect as a part of your installation domestic on the inverter. Consumers connected to the inverter will be always powered even failure of the electric distribution network. In addition, these consumers will be powered for free!
Converter Pure sine
The WKS is an inverter pure sine voltage (pure sine wave) that reproduces a stream of similar quality to that of the public network. It can be used to power any device.
60A maximum charge current
The integrated WKS a charge controller MPPT developing a maximum current of 60 a.
MPPT regulator
The WKS also owns the MPPT (Maximum Power Point Tracking) technology, that is, that he is constantly looking the maximum power point, which allows to get the best performance of the photovoltaic panels. In addition to providing increased energy to a facility, it optimizes the battery and prolongs their life. He scans the on-board tension to find the point of maximum power output and is capable of adapting the power provided by the Panel to align the voltage that the battery can receive.
Description of the function of the icons
Indicates that the unit is connected to the sector
Indicates that the unit is connected to the photovoltaic panel
Indicates that the load is supplied by the sector
Indicates that the circuit of the charger works
Indicates that the circuit of the solar charger works
Indicates that the inverter DC circuit / it works
Indicates that the alarm of the unit is disabled
Indicates that Bluetooth is connected
Page display time
Software
WatchPower 1.14
Features
- Inverter pure sine
- 3kW MPPT solar charge controller
- Priority of the adjustable charging source (solar or network)
- Compatible network and generator
- Auto restart
- Protection against overload, temperature and short circuits
- Smart battery for a longer service life of the
- Cold start function
- USB port
- Deported integrated display
POWER | 3000VA / 3000W |
AC INPUT | |
Voltage | 230 VAC |
Voltage range | 110-280 VAC |
Frequency | 50 Hz / 60 Hz (auto detection) |
AC OUTPUT | |
Regulation of the voltage AC (Batt. Mode) | 230VAC ± 5% |
Peak power (5 sec) | 6 000VA |
Performance | 93% |
Transfer time | 0 ms |
output | Pure sine |
BATTERY AND AC CHARGER | |
Voltage nominal battery | 24 VDC |
Types of batteries | AGM, GEL, open (configurable) |
Algorithm of load | 3 steps |
Voltage in floating | 27 VDC |
Overload protection | 34 VDC |
Maximum charge current | 60A (adjustable) |
SOLAR CHARGER | |
Power max PV | 1500 W |
MPPT operating range | 30 ~ 115 VDC |
Maximum PV open circuit voltage | 145 VDC |
Load current max | 60A |
Max performance | 98% |
Consumption standby | 2 W |
PHYSICS | |
Dimension D x W x H (mm) | 140 x 303 x 525 |
Weight (kgs) | 13 |
ENVIRONMENT | |
Moisture | 5% to 95% |
Operating temperature | 0 ° C - 55 ° C |
Storage temperature | -15 ° C - 60 ° C |
Data sheets and documentation
- Number of Reviews : 4
- Average Grade : 4.5 /5
- J. Herve
- the 11/03/2022
4/5
- A. Anonymous
- the 07/05/2021
5/5
- A. Anonymous
- the 26/07/2020
4/5
- A. Anonymous
- the 25/04/2019
5/5
Specifications
24V | |
13 kg | |
Monophasé | |
303 mm | |
525 mm | |
3000VA |