Three-phase ABB PVS 100TL Inverter View full size

Three-phase ABB PVS 100TL Inverter

ABB

More info

PVS-100

Three-phase ABB PVS 100TL Inverter

The PVS-100/120 inverter is the three-phase inverter connected to the cloud that meets your performance and flexibility needs both for your 400V connected roofing projects but also for your projects of PV power plants connected to the HTA network.


Modular design

 

The high power of the inverter reduces the total number of units, directly reducing your installation, logistics and maintenance costs. Thanks to its compact size and versatile mount, it can be easily installed either flat (e.g. behind a roof acrotery) or vertically against a wall. The inverter and its adjoining cabinet with all the necessary protections allow you to achieve significant savings both on the DC side (no other case needed) and on the AC side (TGBT).


Design flexibility

 

The double-decker topology and six MPTPs ensure sizing flexibility and optimal performance, regardless of the number and model of PV modules used, and regardless of their fouling and shading conditions.


Strengths

 

  • 6 independent MPPT
  • Double-storey topology
  • High performance and IP66 protection index
  • Powers: 100kW (400Vac)
  • Ethernet Datalogger / Built-in Wifi
  • Fast commissioning and maintenance
  • DC/AC box incorporating all protections
  • Vertical or horizontal installation
  • Remote monitoring and update via Aurora Vision®
  • Communication Modbus TCP/RTU Sunspec

Characteristics 

 

ModelPVS 100 TL
As a starter
Absolute maximum DC input voltage (Vmax,abs)1000v
Start-up DC input voltage (Vstart)420V (400... 500 V)
DC operating input voltage range (Vdcmin... Vdcmax)360... 1000 V
DC rated input voltage (Vdcr)620V
Nominal DC Input Power (Pdcr)102,000W
Number of independent MPPT6
DC voltage range (VMPPTmin... VMPPTmax) in Pacr480... 850V
Maximum ™-in power for each MPPT (PMPPT,max)17500 W [480V≤VMPPT≤850V]
Maximum DC input intensity for each MPPT (Idcmax)36 A
Maximum short-entry current (Iscmax) for each MPPT50 A 1)
Number of pairs of DC entries for each MPPT4
DC Connection TypeConnectors 2)
Entry protection
Protection against polarity reversalYes, from a limited power source
Protection against entry surges of each MPPT - ParafoudresType 2 with surveillance
Isolation control of the photovoltaic fieldAccording to IEC62109
DC Switch Features for Each MPPT50 A / 1000 V
Fuses15 A / 1000 V 3)
Monitoring chain currentsSX2: Monitoring of 24 SX input currents: Monitoring of the 6 MPPT currents
On the way out
Type of ac-network connectionTriphasé 3P-PE or 3P-N-PE
Rated AC Power (Pacr @cos-1)100,000 W
Maximum AC Output Power (Pacmax @cos-1)100,000 W
Maximum AC Output Power (Pacmax @cos-1)100,000 VA
Rated AC network voltage (Vac,r)400 V
AC voltage range320...480 V 4)
Maximum AC output intensity (Iac,max)145 A
Nominal network frequency50 Hz / 60 Hz
Network frequency range (fmin... fmax)45...55 Hz / 55... 65 Hz 5)
Nominal power factor and setting range> 0.995, 0... 1 inductive/capacitive with maxi. Smax
Total harmonic distortion rate< 3%
Maximum section allowed185mm2 Cu or Alu
AC connection typeAlu/Cu beach connection, 4x PE M40 - 1x PE M25 for individual unipolar cables (or optional 1x PE M63 for a multipolar cable)
Exit protection
Anti-island protectionAccording to local standards
Maximum caliber of AC external protection225 A
Surge protection - replaceable PF modulesType 2 with surveillance
Operational performance
Maximum return (maximum)98.4%
Weighted return (EURO)98.2%
Communication
Integrated communication interface1x RS485, 2x Ethernet (RJ45), WLAN (IEEE802.11 b/g/n - 2.4 Ghz)
User Interface4 LEDs, User Web Interface
Communication protocolsModbus RTU/TCP (Sunspec)
MonitoringWeb Interface, Mobile Application
Remote monitoring servicesAccess to the Aurora Vision monitoring portal
Advanced featuresIntegrated Datalogger, Data Transfer to the ABB Cloud
Environmental settings
Room temperature range-25...-60 degrees Celsius power reduction > 40 degrees Celsius
Relative humidity4%... 100% condensation
Noise emissions level68dB(A) - 1m
Maximum operating altitude2000m
General features
Environmental Protection IndexIP66 (IP54 fan block)
CoolingForced air
Dimensions (H x l x P)869x1086x419 mm
Weight 70kg power module; 55kg DC/AC box set
Fixing sriersFor a "wall" or "ground" pose
Security
Isolation levelNo transformer
MarkingThis
CEM and safety standardsIEC/EN 62109-1, IEC/EN 62109-2
Network standards (check availability with your sales channel)DIN VDE 0126-1-1A1 VFR2014, CEI 0-16, IEC 61727, IEC 62116, IEC 60068, IEC 61683
Variations available (Module/Box)
Power modulePVS-100-TL-POWERMODULE-400
24 fuse-protected DC entries on the two polarities - inter-dry DC - monitoring of the 24 DC entries - inter-dry AC - DC and AC Type 2WB-SX2-PVS-100/120-TL
24 fuse-protected DC entries on a single pole - inter-dry DC - monitoring of the 6 MPPT - DC and AC Type 2WB-SX-PVS-100/120-TL
Option available
Multipolar AC Cable Plate 1x PE M63 - 1x PE M25MULTICORE AC PLATE

Specifications

Maximum PV input voltage1000 V
Weight70 Kg
Power100000 VA
Monophasé / TriphaséTriphasé
Nombre de MPPT6 MPPT