Sofar Solar 80KTLX-G3 three-phase inverter
More info
Sofar Solar 80KTLX-G3 three-phase inverter
Maximum efficiency up to 98.7
Compatible with 500W+ PV modules
Type II SPD for DC and AC sides, optional: Type I
Low starting voltage, wide MPPT voltage range
6 MPP trackers with 1.5 times DC overload
Long-term overload capacity of 110% AC
SOFARSOLAR's latest lightweight solution for C&I projects
The SOFAR 60...80KTLX-G3 inverter series is SOFARSOLAR's latest state-of-the-art solution for C&I projects. Its high-end components and features make it the ideal solution for C&I projects. Its high-end components and features make it the ideal partner for your C&I application.
Some highlights at a glance
• Fully compatible with high current and large cell (210mm) solar modules - for increased efficiencies
• 6 MPPT - for flexible system planning
• High power density - to reduce installation and operation and maintenance costs
• Lightweight and compact design - for user-friendly installation
• Supports aluminum cables - for reduced upfront costs
• Power limitation
Characteristics
Model | SOFAR - 80KTLX-G3 |
Input (DC) | |
Recommended maximum PV input power | 120000 |
Number of MPP trackers | 6 |
Number of DC entries | 2 for each MPPT |
Max. input voltage (V) | 1100 |
Starting voltage (V) | 200 |
Nominal input voltage (V) | 620 |
MPPT Operating Voltage Range (V) | 180-1000 |
Full MPPT power in voltage range (V) | 550-800 |
Maximum input current MPPT (A) | 6*40 |
Max. input short-circuit current per MPPT (A) | 6*60 |
Output (AC) | |
Rated power (W) | 80000 |
Max power in AC (VA) | 88000 |
Max. output current (A) | 133,3 |
Rated network voltage | 3 / N / PE, 230 / 400 |
Network voltage range | 310 – 480 Vac (according to local standard) |
Nominal network frequency | 50 / 60 Hz |
Network frequency range | 45 – 55 Hz / 55 – 65 Hz (according to local standard) |
Adjustable active power range | 0 – 100% |
THDi | < 3% |
Power factor | 1 default (adjustable +/-0.8) |
Performance | |
Maximum efficiency | 98,70% |
Weighted European efficiency | 98,20% |
Protection | |
DC reverse polarity protection | Yes |
Anti-islanding protection | Yes |
Protection against leakage currents | Yes |
Monitoring of grounding defects | Yes |
Monitoring each string | Yes |
Return power limitation | Yes |
DC switch | Optional |
Surge arrester input / output | PV: type II standard, optional: type I. AC: type II standard |
Communication | |
Standard mode of communication | RS485/WiFi/Bluetooth, optional: Ethernet |
General data | |
Ambient temperature range | -30°C – 60°C |
Nighttime consumption (W) | < 2 W |
Topology | Without transformer |
Degree of protection | IP66 |
Permitted relative humidity range | 0 – 100% |
Maximum operating altitude | 4000 m |
Weight (kg) | 53 |
Cooling | Fan |
Dimensions (mm) | 687*561*275 |
Display | LCD, App via Bluetooth |
Guarantee | 10 years, optional: bis 20 years |
Standards | |
EMC | EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
Safety standards | IEC 62109-1/2, IEC 62116, IEC 61727, IEC 61683, IEC 60068 (1,2,14,30), IEC 60255 |
Network Standards | VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, IEC 0-21 / IEC 0-16, UNE 206 007-1, EN 50549, G99, EN 50530 |
Specifications
MPPT | |
Triphasé | |
6 MPPT | |
12000VA |